Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Circ Cardiovasc Interv ; : e013579, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38629273

RESUMEN

BACKGROUND: The prognostic impact of left atrial appendage (LAA) patency, including those with and without visible peri-device leak (PDL), post-LAA closure in patients with atrial fibrillation, remains elusive. METHODS: Patients with atrial fibrillation implanted with the WATCHMAN 2.5 device were prospectively enrolled. The device surveillance by cardiac computed tomography angiography was performed at 3 months post-procedure. Adverse events, including stroke/transient ischemic attack (TIA), major bleeding, cardiovascular death, all-cause death, and the combined major adverse events (MAEs), were compared between patients with complete closure and LAA patency. RESULTS: Among 519 patients with cardiac computed tomography angiography surveillance at 3 months post-LAA closure, 271 (52.2%) showed complete closure, and LAA patency was detected in 248 (47.8%) patients, including 196 (37.8%) with visible PDL and 52 (10.0%) without visible PDL. During a median of 1193 (787-1543) days follow-up, the presence of LAA patency was associated with increased risks of stroke/TIA (adjusted hazard ratio for baseline differences, 3.22 [95% CI, 1.17-8.83]; P=0.023) and MAEs (adjusted hazard ratio, 1.12 [95% CI, 1.06-1.17]; P=0.003). Specifically, LAA patency with visible PDL was associated with increased risks of stroke/TIA (hazard ratio, 3.66 [95% CI, 1.29-10.42]; P=0.015) and MAEs (hazard ratio, 3.71 [95% CI, 1.71-8.07]; P=0.001), although LAA patency without visible PDL showed higher risks of MAEs (hazard ratio, 3.59 [95% CI, 1.28-10.09]; P=0.015). Incidences of stroke/TIA (2.8% versus 3.0% versus 6.7% versus 22.2%; P=0.010), cardiovascular death (0.9% versus 0% versus 1.7% versus 11.1%; P=0.005), and MAEs (4.6% versus 9.0% versus 11.7% versus 22.2%; P=0.017) increased with larger PDL (0, >0 to ≤3, >3 to ≤5, or >5 mm). Older age and discontinuing antiplatelet therapy at 6 months were independent predictors of stroke/TIA and MAEs in patients with LAA patency. CONCLUSIONS: LAA patency detected by cardiac computed tomography angiography at 3 months post-LAA closure is associated with unfavorable prognosis in patients with atrial fibrillation implanted with WATCHMAN 2.5 device. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03788941.

2.
Int J Cardiol ; 397: 131640, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38065326

RESUMEN

BACKGROUND: The residual device patency (RDP) after left atrial appendage closure (LAAC) with the LACbes device has not been specifically explored in atrial fibrillation (AF) patients. This study aims to explore the incidence, impact and predictors of RDP detected by cardiac computed tomography angiography (CCTA) post LAAC. METHODS: AF patients implanted with the LACbes device were prospectively enrolled. CCTA device surveillance was performed at 3 months post-procedure. Major adverse events (MAEs), including stroke/transient ischemic attack, major bleeding and all-cause death, were evaluated. RESULTS: Among 141 patients with CCTA surveillance, 56 (39.7%) showed no visible leak and 85 (60.3%) showed RDP. During the median follow-up of 443 [232, 706] days, the presence of RDP was not associated with an increased risk of MAEs (adjusted hazard ratio [HR]: 4.07, 95% confidence interval [CI]: 0.49-34.24, p = 0.196), while peri-device leak (PDL) at the lobe was associated with heightened risks of MAEs (adjusted HR: 6.85, 95% CI: 1.62-28.89, p = 0.009). In patients with PDL at the lobe, antiplatelet after 6 months (HR: 0.20, 95% CI: 0.05-0.91, p = 0.038) was independent protective predictor of MAEs. Besides, current smoking (odds ratio [OR]: 7.52, 95% CI: 2.68-21.08, p < 0.001) and maximum diameter of LAA orifice (OR: 1.16, 95% CI: 1.00-1.34, p = 0.048) were independent predictors of PDL at the lobe. CONCLUSIONS: Presence of PDL at the device lobe detected by CCTA at 3-month post LAAC with LACbes is associated with unfavorable prognosis in AF patients. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03788941.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Incidencia , Cierre del Apéndice Auricular Izquierdo , Prótesis e Implantes/efectos adversos , Accidente Cerebrovascular/epidemiología , Resultado del Tratamiento
3.
Am J Cardiol ; 204: 312-319, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37567023

RESUMEN

Left atrial appendage closure (LAAC) proved to be noninferior to oral anticoagulation (OAC) in nonablated patients with atrial fibrillation (AF). This study aimed to compare the efficacy and safety of LAAC with those of OAC therapy in patients after AF ablation. This study included patients who underwent catheter ablation (CA) of AF between January 2016 and December 2020. The cohort was divided into CA + LAAC and CA + OAC, where propensity score matching was used to select controls, and each group contained 682 subjects. The enrolled patients' mean age was 70.34 ± 8.32 years, and 47.3% were female; their CHA2DS2-VASc score was 3.48 ± 1.17. Baseline characteristics were similar between groups. After a 3-year mean follow-up, the incidence of thromboembolic events was 1.25 and 1.10 and that of major bleeding events was 0.65 and 1.72 per 100 patient-years in the CA + LAAC, and CA + OAC groups, respectively. The rate of thromboembolisms and major adverse cardiovascular events was similar between the 2 groups (hazard ratio [HR] 1.162, 95% confidence interval [CI] 0.665 to 2.030, p = 0.598, HR 0.711, 95% CI 0.502 to 1.005, p = 0.053); however, that of major bleeding and all-cause death was significantly reduced with LAAC (HR 0.401, 95% CI 0.216 to 0.746, p = 0.004, HR 0.528, 95% CI 0.281 to 0.989, p = 0.046). There was no significant difference in periprocedural complications (p >0.05) and the rate of AF recurrence (OAC vs LAAC: 39.44% vs 40.62%, p = 0.658). LAAC is a reasonable and safer alternative to OAC therapy in high-risk patients after AF ablation.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Accidente Cerebrovascular , Tromboembolia , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Apéndice Atrial/cirugía , Hemorragia/inducido químicamente , Tromboembolia/epidemiología , Tromboembolia/etiología , Tromboembolia/prevención & control , Anticoagulantes/uso terapéutico , Ablación por Catéter/efectos adversos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...